Wskaźnik w FT-897
Szukałem kiedyś takich informacji na zagranicznych forach. Oto co udało mi się wtedy znaleźć:

Pierwsze info:

0 Mark 1.14:1
1 1.33:1
2 1.55:1
3 1.65:1PWR Folds Back
4 1.81:1
5 2.1:1
6 2.5:1
7Mark 3.0:1HI SWR "HSWR" Flashes

Drugie info

As for the actual reading? I bought one used to play with a couple of years ago. I actually thought the thing was dead in the SWR department. I went through the whole realignment procedure without avail. On the unit I had, anything under 1.3:1 was one blob. Two blobs was about 1.5:1, and 3 blobs, about 1.6:1. It takes about 4:1 to get all of the display to show.

Generally, if my SWR is below 4 on the 15 scale the rig doesn't fold back power. From tests I've done before with my SWR analyzer and a tuner, that's probably a hair over 2.25:1

At 6 out of 15, the "SWR" indicator comes on and flashes. I think that should happen at about 3:1 SWR.


Odpowiada to generalnie prawdzie.


  PRZEJDŹ NA FORUM