Złącza UKF
Złącza BNC, N.... .....
http://www.amphenolrf.com/faq/technical/what-is-insertion-loss-and-how-is-it-specified.html
What is Insertion Loss and how is it specified?
Dec 23, 2014

Insertion Loss, expressed in dB is defined as 10*log (Po/Pi) where Po= Power Out and Pi=Power In. There are 3 main causes of Insertion Loss: Reflected losses, Dielectric losses and Copper losses. Reflected losses are those losses caused by the VSWR of the connector. Dielectric losses are those losses caused by the power dissipated in the dielectric materials (Teflon, rexolite, delrin, etc.). Copper losses are those losses caused by the power dissipated due to the conducting surfaces of the connector. It is a function of the material and plating used.
In general, the insertion loss of a connector is on the order of a few hundredths to a few tenths of a dB. As with VSWR, it can be specified as a “flat line limit” or as a function of frequency. A BNC connector is specified at .2 dB maximum when tested at 3 Ghz. For the SMA, the requirement is .06*SQRRT Frequency in GHz when tested at 6 Ghz. For example, at 4 Ghz, the requirement would be .06*2 or .12 dB max. Although the connectors are specified to operate over a wide frequency range, they are only specified for testing at particular frequency because the test procedure required to obtain accurate measurements of such small losses is a very precise, and time consuming process.
Albo tu:
http://www.qsl.net/vk3jeg/pl259tst.html
aniołek


  PRZEJDŹ NA FORUM